Table of Contents
AccuStar Alpha Track Test Kit AT 100 Review: Radon Gas Testing

Here we bring to you AccuStar’s user–friendly and greatest home radon detector kit, ALPHA TRACK TEST KIT AT–100 Review, to develop, maintain, and sustain a happy, healthy, and safe environment for you, your family, and your friends.
What Is The Alpha Track Test Kit At 100?
AccuStar’s Alpha Track Test Kit AT–100 is used for long-term radon gas testing. This long-term test provides a better depiction of radon concentrations across different seasons and building conditions in your home environment. The radon exposure time to the Alpha Track device is typically 3 to 12 months, and this kit is a small-packet, big-bang kind of device.
This type of electrochemical system was found to be superior to chemically etched alpha-track radon detectors.
Accuser Alpha Track Test Kit, At 100 Radon Gas Test Kit -Product Specification :
| BRAND | Accustar |
|---|---|
| TYPE | Radon gas testing kit (diffusion based track detector) |
| MODEL NUMBER | AT 100 |
| MEASUREMENT | pCi/L |
| DIMENSION | 6.3 X 3.6 X 1.2 INCHES |
| COLOR | Black |
| POWER | Electrochemical etching process |
| MANUAL/ AUTOMATIC | Manual test kit |
| MADE IN | USA |
| WARRANTY | 1 year warranty against system failure |
How Does the Alpha Track Radon Test Kit At 100 Work?

The Alpha Track Test Kit AT–100 was originally designed in 1986 and is a diffusion-based radon track detector. Each detector is given a unique barcode and sealed in an airtight pouch with two data sheets to be filled out before sending the device back for the test.
It basically strains out dust and radon progeny through a structural filter integral to the house, resulting in increased structural stability. Alpha Track Test Kit AT–100 has an improved design with a hemispherical base. This base type is designed to maximize sensitivity and create a more uniform track distribution, resulting in better statistics.
You need to place the kit on the lowest living level of your house, because radon levels are highest at lower levels. After long-term exposure to the air for 3 to 12 months, you would need to ship this kit back to AccuStar Labs for the results. Fill in the details on the documents provided with this device, seal it in the prepaid shipping envelope, and send it back to the lab. The most accurate test results would be available to you within 8 to 10 business days.
Specifications Alpha Track Radon Test Kit At 100
· Barcode is readable.
· Twin removable serial labels.
· Clear read pouch reducing serial errors.
· Electrochemical etching for a better track.
· Large foil area counted for better statistics.
· Hemispherical base for better track distribution.
· Rough structural filter for both indoor and outdoor use.
· Electrically conducting housing reduces charge effects and clustering.
· Alpha Track Test Kit AT–100 is counted with computer-aided image analysis equipment.
Benefit Of Using Alpha Track Test Kit At–100
· No.1 rating by a leading National Consumer Advocacy Group
· U.S. EPA verified product
· Accurate radon measurement
What’s Not Good
· Requires a year-long exposure
· You will have to send the device back to get the results
· Testing for the results may also take about 10 days to revert
Frequently Asked Questions for Accustar Alpha Track Test Kit AT 100
Q1: Do we have to pay any testing fee while the kit is back for testing?
Answer: No, it is included in the kit price.
Q2.Does the test outcome give you one number as an average, or does it show you how the number fluctuates over the course of the month?
Answer: The lowest exposure for the AccuStar Alpha Track test is 90 days, up to the highest exposure of 365 days (one year). The test results will provide the overall average length of exposure. It will not indicate the deviation levels during this time frame.
Q3.How do we begin with the testing process?
Answer: There are no additional steps required to start the test. Simply taking out the device from the clear plastic packaging starts the test. No extra steps are needed.
Q4.What should one avoid doing while measuring radon with this testing device?
Answer: The test should be performed under normal living conditions. The temperature is 50-90 degrees, and the humidity is 20-75 percent. The device will not calibrate outside of these test conditions, and AccuStar Labs cannot report the result to you. As far as humidity is concerned, in the home being tested, always keep in mind: the lower, the better. If the area you are testing is very damp or moist, do not test until it dries out.
Do not test in a kitchen, laundry area, bathroom, crawl space, furnace room, hallway, elevator shaft, stairwell, or closet.
Q5.Should I be careful about where I store an AlphaTrack device before I use it?
Answer: Yes. Alpha track devices should be stored in a conditioned space. Refrain from keeping the alpha track devices in your vehicle, as extreme temperatures can affect their sensitivity.
Q6: Do I need my serial or device numbers to get results?
Answer: Yes, you do. To maintain the privacy of their customers, AccuStar requests that they keep a copy of your device numbers. If you contact the lab for test results without your device numbers, you will be redirected to the company you purchased your kit from to obtain them.
About Accustar
Professional Radon Laboratory Services Since 1984. AccuStar is the only laboratory in the United States providing accurate, easy–to–use radon testing products and radon training programs for professionals. It’s the only company to use electrochemical processes to manufacture its alpha-track foils. AccuStar, along with RadonAway, is the world’s leading manufacturer of radon fans, a brand of Spruce Environmental Technologies, and is a pioneer in the radon industry for over 15 years. Their products and laboratories are NRSB and NEHA certified. They are also licensed in all the states that have such requirements